![]() HP SPP 2/14 Hanging while loading Hi all, I just downloaded and burned the February 2014 Service Pack for ProLiant, and upon attemtping to run it in a DL380G5 system (which would run the one from 9/13 just fine), it gets to the loading bar, loads for awhile, then stops at a white screen where in the bottom left corner it just shows 'waiting for. The Service Pack for ProLiant (SPP) is a comprehensive systems software and firmware update solution, which is delivered as a single ISO image. This post production SPP uses Smart Update Manager (SUM) as the deployment tool and contains updates for ProLiant Gen8 systems. Aug 19, 2018 - The upgrade procedure will become much easier since everything will be done now from 1 HP SUM which will have all components inside. We have trouble to update two servers with HP SUM. First one is a DL320 G6. Creada para ser su ayuda idonea debi pearl pdf download. It boots from CD (interactive upgrade), HP start screen appears and progress bar loads up to 100% but nothing else happens. Seems to stand still on this point. We tried to boot from USB-stick too - but same behaviour. Second server is a DL 320 G6. Also boots from CD (or USB). HP loading-screen appears, loads up to 100% and after that it changes to a white screen (Firefox?) and nothing else happens. In the bottom left corner 'Waiting for 127.0.0.1' appears. Also stands still at this point. Any help would appreciated. Yes, it’s that time of year for HP to release their updated HP Service Pack for ProLiant, which is now up to version 2012.06.0 (B). You can find the 514 page release notes (yes that is not a typo, 514 pages). This update includes a number of fixes to SUM (now up to version 5.1), firmware for a slew of Gen8 servers, firmware updates for other servers, and driver updates for Windows/Linux. As always these support packs have 12 months of support. To download the HP SPP click. You can find a good documentation matrix for this and previous versions. Administrators have a few different options for updating HPE infrastructure components. One popular way to update HPE firmware, drivers, and Smart Components is utilizing Service Pack for Proliant (SPP) and the HP SUM tool. What are SPP and SUM? SPP – Service Pack for Proliant is a collection of firmware, drivers and Smart Components that are deployed to your environment via the SUM tool. SPP is packaged as an ISO. SUM – HP Smart Update Manager is the tool utilized to deploy updates to HP ProLiant Servers, Integrity Servers, BladeSystem infrastructure, and HP Moonshot Servers. SUM, by default, opens as a GUI. It can also be run in interactive CLI, CLI, or Linux RPM mode. How does SUM and SPP work? SUM discovers nodes in your infrastructure and records their current firmware and drivers. It then checks the existing firmware/drivers against the SPP and provides update recommendations for admins to apply. How to Update HPE Enclosures, Servers, and Fabric Components Now that we have that under control. Download Hp Service Pack For Proliant ServersLet’s look at how to deploy updates to your HPE chassis, servers, and fabric components. If you haven’t done so already, download the. The SPP should come with HP SUM. After you have the pertinent downloads, mount the SPP iso locally. Locate and run the launch_hpsum batch file. As the file executes, HP SUM will open in your browser. First, we check to see if the Baseline was added automatically. If not, we will manually add the Baseline. The Baseline is the update level our nodes will be compared against. To view or add Baselines, click the Baseline Library under HP Smart Update Manager drop-down arrow. If the baseline was automatically added, you will see it recorded. If not, select Add Baseline. As we are adding the Baseline from the SPP ISO, select Browse HP Sum server path for the Location Type. Under Location Details, Browse to the packages folder of your mounted ISO. Older SPP versions held the baseline in hp/swpackagesfolder. Once added, the Baseline will begin to populate. After the Baseline has been inventoried, we will add our infrastructure nodes. These nodes are devices such as Onboard Administrator, Server Blades, Virtual Connects, Brocades, etc. Under the Smart Update Manager drop-down, select Nodes. From the nodes page, click Add Node. Enter the pertinent information for the node; including IP/DNS, Node Type, Baseline, and Credentials. In this instance, we are adding the Onboard Administrator of a BladeSystem enclosure. Checking the Automatically Add Associated Nodes allows us to gather all additional nodes in the enclosure. Click Add when finished. With the node added, select Inventory. Here current firmware/drivers are discovered and updates will be recommended. As the nodes are inventoried, shapes will indicate different action items. Green Square – Node is at its assigned baseline Yellow Triangle – Update required/Ready for deployment Red Circle – Could not inventory/Incorrect username or password. Nick cave full discography torrent. Next, we’ll look at a node where an update is required.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |